Program lockout switch:
The switch must be in the “SET” position in order to
access the program modes.
1. Disconnect the dispenser from the power source.
2. Remove the 4-40 screws and the top cover.
3. Use a small screwdriver to move switch to set
position.
4. Install top cover, connect dispenser to power
source.
Manual Energy Saver Mode:
The energy save mode will allow the tank temperature
to drop down to 140°F (60°C).
1. Simultaneously press and release the (+) and (-)
to “manually” activate energy save mode.
2. The display will alternately flash between 140
and the current temperature to indicate it is in
the energy save mode.
3. Repeat procedure to exit energy save mode.
Programming the dispenser:
1. Press and hold upper hidden button (bottom
center of “BUNN” logo) until “P1” is displayed.
Adjusting temperature:
The switch must be in the “SET” position in order to
access the program modes.
1. Press and hold “TEMP” button until display
flashes.
2. While display is flashing, press and release the
(+) to increase or (-) to decrease temperature.
NOTE: If unit is “E” model, temp will stop at 205°F
(96°C). If unit is “X” model, temp display will jump
from 205°F (96°C) to 212°F (100°C).
Step forward
Step backward
Continued
6
PROGRAMMING
SET
LOCK
44306 022111