Adjust tank temperature
(190° F maximum)
Adjust minimum tank ready temper-
ature for lockout (185° maximum)
Adjust hopper motor speed
for station selected
TANK TEMP XXX°
(-) EXIT (+)
READY TEMP XXX°
(-) EXIT (+)
DRINK STRENGTH
(-) XX (+)
XX° CAL XX°
(-) Tank Temp (+)
235 REFILL 155
(-) EXIT (+)
PORTION CONTROL ?
NO EXIT YES
Calibrate temperature probe
Set refill probe threshold
Select Portion Control
Dispensing
HEAD# TIME
(-) ##.# (+)
Set Dispense Time
In Seconds
Auger Delay
(-) .XX sec (+)
Set delay start of hopper after dilution
valve opens in station selected
DISPENSE LOCKOUT
NO EXIT YES
RINSE ALARM ?
NO EXIT YES
HEAD 1 DISABLE ?
NO EXIT YES
SET PASSWORD ?
(-) XXXX (+)
Enables lockout of dispensing if below
minimum water temperature
Enables rinse alarm
Disables all functions and dispensing
for station selected
Allows password to be set to pre-
vent altering setup functions
ENABLE ADS ?
NO EXIT YES
ENTER ASSET # ?
EXIT YES
Enables “ADS” to be displayed
on LCD door display
Enter asset number of machine
Enables service agent telephone
number to be displayed
TEST SWITCHES ?
Use Switch To Test
TEST HEATER ?
EXIT YES
TEST REFILL ?
EXIT YES
TEST HOT WATER ?
EXIT YES
TEST AUGERS ?
DISPENSE TO TEST
TEST DISP HEADS
DISPENSE TO TEST
Allows testing of dispense
switches
Allows manually activating
tank heater
Allows manually activating
refill valve
Allows manually activating hot
water valve (optional)
Allows manually activating
hopper motors
Allows manually activating dis-
pense valves & whipper motors
ENABLE SERVICE #
NO EXIT YES
GLOSSARY
FACTORY DEFAULTS
NO YES
Resets all functions to factory
defaults, and password to 0
SET CUP SIZE
EXMPL TIME
Select setting cup size by Time (seconds) or
by Example (Portion Control models only)
DISPENSE TO ADD
REPEAT SAVE
Press same dispense button to top off
cup, or press save to lock in dispense
time, or, press repeat to erase dispense
time and repeat process.
38987 032306